Radiography
Volume 16, Issue 4 , Pages 304-313, November 2010

Impact of focal spot size on radiologic image quality: A visual grading analysis

Diagnostic Imaging, Biological Imaging Research, UCD School of Medicine and Medical Science, Health Science, Belfield, UCD, Dublin 4, Ireland

Received 17 October 2008; received in revised form 27 May 2009; accepted 28 February 2010. published online 21 June 2010.

Abstract 

Fine and broad focal spot sizes are available on general X-ray tubes. Excessive use of fine focus can impact on tube life and whilst it is established that fine focal spot size reduces geometric unsharpness, the extent of this benefit on clinical image quality is unclear.

The current cadaver-based work compares images produced with effective focal sizes of 0.8mm and 1.8mm. Four projection types were included, lateral ankle, antero–posterior (AP) knee, AP thoracic spine and horizontal beam lateral (HBL) lumbar spine, and a visual grading analysis was used to assess visibility of anatomical criteria. Five clinicians scored each image using a 1–4 scoring scale, a reference image was employed for standardization and a Mann–Whitney U statistical test compared results derived from each focus. Radiation doses were monitored using a dose area product (DAP) meter.

Statistical analyses demonstrated no significant differences between images produced at each focus, although a relationship between body part thickness and number of criteria with a higher (non-significant) score for the fine focus compared with the broad focal spot size was demonstrated. Choice of focus had no radiation dose implications.

Fine foci X-ray sources are used predominantly for extremity imaging to enhance visualization of fine detail such as trabecular patterns, yet there is no evidence to support this practice. The argument for regular employment of fine foci, particularly for the type of acquisition and display devices used in this study, needs to be revisited.

Keywords: Geometric unsharpness, Cadaver, X-ray projection

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1078-8174(10)00032-5

doi:10.1016/j.radi.2010.02.007

Radiography
Volume 16, Issue 4 , Pages 304-313, November 2010