Radiography
Volume 14, Issue 3 , Pages 178-183 , August 2008

Validation of an external ultrasound device for bladder volume measurements in prostate conformal radiotherapy

  • Evelyn O'Shea

      Affiliations

    • Department of Radiation Oncology, St. Luke's Hospital, Highfield Road, Rathgar, Dublin 6, Ireland
    • Corresponding Author InformationCorresponding author. Tel.: +353(0) 1 4065107; fax: +353(0) 1 4974886.
  • ,
  • John Armstrong

      Affiliations

    • Department of Radiation Oncology, St. Luke's Hospital, Highfield Road, Rathgar, Dublin 6, Ireland
  • ,
  • Tom O'Hara

      Affiliations

    • Infosight Training and Consultancy, Midlands Innovation and Research Centre, Athlone, Ireland
  • ,
  • Louise O'Neill

      Affiliations

    • Department of Physics, St. Luke's Hospital, Dublin, Ireland
  • ,
  • Pierre Thirion

      Affiliations

    • Department of Radiation Oncology, St. Luke's Hospital, Highfield Road, Rathgar, Dublin 6, Ireland

Received 19 September 2006 ,Revised 23 March 2007 ,Accepted 7 June 2007.

References 

  1. Hoogeman MS, van Herk M, Yan D, Boersma LJ, Koper PC, Lebesque JV. A model to simulate day-to-day variations in rectum shape. Int J Radiat Oncol Biol Phys. 2002;54(2):615–625
  2. Ten Haken RK, Forman JD, Heimburger DK, Gerhardsson A, McShan DL, Perez-Tamayo C, et al. Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder. Int J Radiat Oncol Biol Phys. 1991;20(6):1317–1324
  3. Higgins PD, Weaver R, Dusenbery KE. Evaluation of bladder dose in intensity-modulated radiation therapy of the prostate. Med Dosim. 2006 Fall;31(3):197–200
  4. O'Doherty UM, McNair HA, Norman AR, Miles E, Hooper S, Davies M, et al. Variability of bladder filling in patients receiving radical radiotherapy to the prostate. Radiother Oncol. 2006;79(3):335–340
  5. Zellars RC, Roberson PL, Strawderman M, Zhang D, Sandler HM, Ten Haken RK, et al. Prostate position late in the course of external beam therapy: patterns and predictors. Int J Radiat Oncol Biol Phys. 2000;47(3):655–660
  6. De Groef S, Van Hellemont J, Vandevelde G, Van Uytsel L. Reproducible bladder filling during conformal RT of the prostate. Radiother Oncol. 1998;35(Suppl. 1):S251;[abstract]
  7. Pinkawa M, Asadpour B, Gagel B, Piroth MD, Holy R, Eble MJ. Prostate position variability and dose-volume histograms in radiotherapy for prostate cancer with full and empty bladder. Int J Radiat Oncol Biol Phys. 2006;64(3):856–861
  8. Villeirs GM, De Meerleer GO, Verstraete KL, De Neve WJ. Magnetic resonance assessment of prostate localization variability in intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys. 2004;60(5):1611–1621
  9. Brundage M, Lukka H, Crook J, Warde P, Bauman G, Catton C, et al. The use of conformal radiotherapy and the selection of radiation dose in T1 or T2 low or intermediate risk prostate cancer – a systematic review. Radiother Oncol. 2002;64(3):239–250
  10. Armstrong JG. Target volume definition for three-dimensional conformal radiation therapy of lung cancer. Br J Radiol. 1998;71:587–594
  11. Pinkawa M, Fischedick K, Asadpour B, Gagel B, Piroth MD, Eble MJ. Low-grade toxicity after conformal radiation therapy for prostate cancer – impact of bladder volume. Int J Radiat Oncol Biol Phys. 2006;64(3):835–841
  12. ICRU Report 62. Prescribing, recording and reporting photon beam therapy. [Supplement to ICRU Report 50]; 1999. p. 8–9.
  13. Buchali A, Koswig S, Dinges S, Rosenthal P, Salk J, Lackner G, et al. Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer. Radiother Oncol. 1999;52(1):29–34
  14. Lebesque JV, Bruce AM, Kroes AP, Touw A, Shouman RT, van Herk M. Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer. Int J Radiat Oncol Biol Phys. 1995;33(5):1109–1119
  15. Montana GS, Fowler WC. Carcinoma of the cervix: analysis of bladder and rectal radiation dose and complications. Int J Radiat Oncol Biol Phys. 1989;16(1):95–100
  16. Vordermark D, Schwab M, Ness-Dourdoumas R, Sailer M, Flentje M, Koelbl O. Association of anorectal dose-volume histograms and impaired fecal continence after 3D conformal radiotherapy for carcinoma of the prostate. Radiother Oncol. 2003;69(2):209–214
  17. Greco C, Mazzetta C, Cattani F, Tosi G, Castiglioni S, Fodor A, et al. Finding dose-volume constraints to reduce late rectal toxicity following 3D-conformal radiotherapy (3D-CRT) of prostate cancer. Radiother Oncol. 2003;69(2):215–222
  18. O'Sullivan JM, Gribbin A, Taylor J, O'Neill L, Cosgrove S, Armstrong JG. Complications of treatment with local field external beam radiotherapy for localized prostate cancer. Clin Oncol (R Coll Radiol). 2000;12(4):217–221
  19. Boersma LJ, van den Brink M, Bruce AM, Shouman T, Gras L, te Velde A, et al. Estimation of the incidence of late bladder and rectum complications after high-dose (70–78 Gy) conformal radiotherapy for prostate cancer, using dose-volume histograms. Int J Radiat Oncol Biol Phys. 1998;41(1):83–92
  20. Mechalakos JG, Mageras GS, Zelefsky MJ, Lyass O, van Herk M, Kooy HM, et al. Time trends in organ position and volume in patients receiving prostate three-dimensional conformal radiotherapy. Radiother Oncol. 2002;62(3):261–265
  21. O'Shea E, O'Neill L, Magee A, Kissane M, Brett C, Burke S, et al. The bladder-filling protocol for prostate 3-DCRT patients in St. Luke's Hospital. Radiography Ireland. 2005;9(1):[Journal of the Irish Institute of Radiography]
  22. Bland M. An introduction to medical statistics. 3rd ed.. Oxford University Press; 2000;p. 268–275

PII: S1078-8174(07)00058-2

doi: 10.1016/j.radi.2007.06.001

Radiography
Volume 14, Issue 3 , Pages 178-183 , August 2008