Radiography
Volume 13, Issue 3 , Pages 173-179, August 2007

A comparison of patient dose levels between 3/4 vessel conventional angiography and computed tomography angiography during examinations to investigate subarachnoid haemorrhage

  • David Spanton

      Affiliations

    • Addenbrooke's Hospital NHS Trust, United Kingdom
  • ,
  • Ruth M. Strudwick

      Affiliations

    • Suffolk College, School of Radiography, Faculty of Health, Rope Walk, Ipswich, Suffolk IP4 1LT, United Kingdom
    • Corresponding Author InformationCorresponding author. Tel.: +44 01473 296693.

Received 16 September 2005; accepted 11 February 2006.

Abstract 

The aim of this study was to investigate and compare the levels of ionising radiation dose received by patients whilst undergoing radiological examination for Subarachnoid haemorrhage by conventional angiography (single and bi plane) and computed tomography angiography. The results obtained from previous examinations have been compared to consider which method of investigation delivers the lowest ionising radiation dose to the patient. Consideration was also given to comparing single plane angiography to bi plane angiography as empirical evidence suggested that radiologists received no formal training and only a small amount of informal training on newly installed equipment at the hospital in which the research was carried out. Would this lead to patients being inadvertently exposed to increased radiation as radiologists familiarised themselves with the equipment?

The dose received by 30 patients examined for SAH by each modality was converted to effective dose (mSv) for comparison. These results were then further compared by removing the lowest and highest recorded doses to eliminate any bias that may have been caused by skewed data. The results showed that CTA consistently delivered a lower dose to patients than single or bi plane angiography and that bi plane delivered a lower mean average dose than single plane angiography, with or without any skewed data.

Keywords: Subarachnoid haemorrhage (SAH), Single plane angiography, Bi plane angiography, Computed tomography angiography (CTA), Radiation dose

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1078-8174(06)00016-2

doi:10.1016/j.radi.2006.02.003

Radiography
Volume 13, Issue 3 , Pages 173-179, August 2007