Computed tomography of the head: An experimental study to investigate the effectiveness of lead shielding during three scanning protocols

  • Lisa Williams

      Affiliations

    • Glan Clwyd, Hospital, North Wales, UK
  • ,
  • Caroline Adams

      Affiliations

    • Department of Radiography, Wales College of Medicine, Biology, Life and Health Sciences, Cardiff University, Heath Park, Cardiff CF14 4XN, UK
    • Corresponding Author InformationCorresponding author. Tel.: +44 29 20 746531; fax: +44 29 20 743836.

Received 2 November 2004; accepted 3 May 2005.

Abstract 

Purpose

The purpose of this experimental study, carried out in 2002, was to investigate the effectiveness of lead shielding during three scanning protocols for Computed Tomography (CT) head examinations.

During CT, the thyroid is irradiated via scattered radiation outside the primary beam. Scientists have proved a definite link between thyroid cancer and radiation but have struggled to quantify the risks from low doses such as those in medical exposures. Children are known to be at higher risks from the effects of radiation than adults.

Method

An anthropomorphic phantom was used to simulate the patient. Shielding in the form of a standard lead thyroid shield was used due to the nature of the rotating X-ray beam involved with CT. Thermoluminescent detector chips were used to measure the approximate dose to the thyroid with and without the application of the shield.

Results

The effectiveness of shielding varied with scanning technique, as did the thyroid dose due to scattered radiation. The lead shield significantly reduced the dose to the thyroid by 46–58% at the surface of the thyroid and by 37–44% within the thyroid tissue at 1cm depth.

Conclusion

In light of the increasing number of CT scanners, and the fact that head scans account for 50% of all CT examinations and 25% of the collective dose from CT to the UK population, it is important that all methods of dose reduction are considered. The use of shielding is a simple yet effective method of dose optimisation that has not been extensively investigated.

Keywords: Dose, Reduction, Thyroid, CT, Lead shielding

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1078-8174(05)00063-5

doi:10.1016/j.radi.2005.05.001

Radiography
Volume 12, Issue 2 , Pages 143-152, May 2006